AEHEALTH LIMITED, is the fast growing POCT company. Manufacture and sales of rapid diagnostic reagents and related equipment in POCT field.

Application areas include small clinics, ambulances, customs, ICU, homes, natural disaster rescue, third- party laboratories and many other industries. Many products and technologies have been approved by CE.

Aehealth’s price-performance products are being extended all over the world, including fluorescence immunoassay analyzer, Nucleic acid extraction, PCR analyzer, enzyme immunoassay analyzer, and relevant reagents. Our products which adopt the first-class and advanced international technology of clinical laboratory are successfully sold in domestic and overseas market. It has achieved extensive compliment and approved by our clients in global market. With the broad-ranged application, perfect quality, simple operation, and reliable performance, our products can satisfy your requirements, not only in its quality, but also in its safety standard.

Impedance method for cells counting, 21 Parameters, 60 samples/ hour, 9.9 uL, 1 network port, 1 RS-232 port, 4 USB ports, 2 reagents + 1 maintenance cleanser, 10.4-inch touch screen, 10℃~30℃ Working Temperature, AC110/115V or AC220/230V, 50Hz Input power:≤150VA, WBC Range: (7.0 ~ 15.0 )× 10 9/ L | CV: ≤2.0% | Carryover: ≤0.5% | Linearity range: (0.0 ~ 300) ×10 / L, RBC range: (3.50 ~ 6.5)× 10 12/ L | Cv: ≤1.5%| Carryover: ≤0.5% | Linearity range: (0.0 ~ 8) ×10 / L, HGB range: 100 ~ 180 g/L | CV: ≤1.5% | Carryover: ≤0.5% | Linearity range: (0.0 ~ 250) g/ L, Platelet: (150 ~ 500) × 10 9/ CV: L ≤4.0% | ≤1% 9 | Linearity range: (0.0 ~ 3000) × 10 / L, AeHealth , Aehealth Ltd, United Kingdom (UK)

AerC-3 Auto Hematology Analyzer is a clinical test instrument with rich functions and easy operation. It can provide 21 parameters and 3 histograms, double channel counting. During the sample analysis process, automatic blockage removal and automatic re-counting ensure accurate and stable test results. Widely used in hospital laboratories, clinical departments, and research centers.

+

P/6,567.00
Linear Range: 10.0-320.0nmol/L, Linear correlation coefficient R ≥ 0.990, Cross-Reactivity:The following substances do not interfere with the T4 test results at the indicated concentrations: TT3 at 500ng/mL,rT3 at 50ng/mL., 10.0nmol/L, within batch C.V. is ≤ 15%; between batches C.V. is ≤ 20%, the relative deviation of the measurement results shall not exceed ± 15% when the accuracy calibrator prepared by TT4 national standard or standardized accuracy calibrator are tested., T4, AeHealth , Aehealth Limited, United Kingdom (UK)

T4 (Total Thyroxine)

Increase:

  • Hyperthyroidism
  • Various thyroiditis
  • Elevated serum TBG

 Decrease:

  • Primary or secondary hypothyroidism
  • Decreased serum TBG
  • Inhibition of T4 to T3 factors (low T3 syndrome)

 

+