The AC6600 Automatic Glycated Hemoglobin HbA1c Analyzer is designed to ensure the accuracy of test results with its high separation liquid chromatographic column.
- Accurate Principle of Methodology - Adopts classical and accurate principle of methodology - Ion exchange liquid chromatography, It is the gold standard of HbA1C analysis, and it is the only analysis method to really separate HbA1C directly by measuring the piecemeal absorbance through continuous test online and obtain the correct area percentage with integration.
- Accurate separation 4-gradient elution - The novel 4-gradient elution for HbA1C can separate accurately glycated hemoglobin with 4-gradient elution of corresponding concentration reagent aiming at HbA1C instead of routine Elution process produced by high and low concentration mixture.
- High Separation Liquid Chromatographic Column - High separation liquid chromatographic column made of imported resin with volume of Φ 9mm x 45mm and weight of 2.5g which is 15 -20 times greater than general micro chromatographic column. High efficiency chromatographic columns for 300 tests ensure the accuracy of test results.
- High Sensitivity 415nm LED Integral Photometer - High sensitivity 415nm LED integral photometer has the characteristics of correct wavelength, stable light source, full aluminum alloy structure, high anti-interference performance, multi-lens focusing, micro cuvettes and high sensitivity. It can accurately record the analysis curve.
- Precision Chromatographic Column and Thermostatic Apparatus - ensure that Chromatographic column and reagent are not affected by environment temperature and effectively guarantees the repeatability and correctness of the test results.
- Real-time summarized chromatogram, Intelligence process detection
Model Name:
AC 6600
Brand:
Audicom
Manufacturer:
Jiangsu Audicom Medical Tech. Co. Ltd.
Origin:
China
TECHNICAL DATA
Specification:
Method: Low Pressure Ion Exchange Liquid Chromatography
Specification:
Testing Item: Glycated hemoglobin HbA1c
Specification:
Testing Scope: 3% ~ 18% | Precision (CV): < 3%, Accuracy (V): <1.5%
Specification:
Testing Time: 4 minutes (reporting), Full-processing 6 minutes (including cleaning column and recovery time)
Specification:
Sample: 5μl venous blood (EDTA anticoagulation), Peripheral finger blood
Specification:
Photometer: 415nm LED Integral flow colorimeter
Specification:
Sampling mode: 20 sample turntable positions, 2 QC positions, 1 emergency positions, 1 cleaning position
Specification:
Reagent matching: 300 tests / 1 pc of column and reagent consumable
Specification:
Report output: IFCC concentration value, NGSP area %, ADAG average Glucose