FIR MED ENTERPRISES
FIR MED ENTERPRISES

Distributor of medical and laboratory supplies, diagnostics, and equipments

Address: Mia Vita Subdivision, Antipolo, Rizal, 1870

Landline: (02) 8985 - 0671

 

Vendor filters

Capacity
Origin
Packaging
Price
Size
Vendor
Brand
Variation: Feature

Vendor productsProducts found: 123

Ask a question
Compact, Fully-automated, Principle: Reverse-Phase Cation Exchange Chromatography | High-Performance Liquid Chromatography (HPLC), Measured items: HbA1c, HbF, Measurement range: HbA1c (3-20%, 9-195 mmol/ mol); HbF (0-100%), Sample volume: Approx. 4 uL(Whole blood or hemolysate), Rack: 5 samples per rack | Max loading capacity: 10 samples, Throughput: 100 seconds per sample | Sampling method: Cap piercing, Detection method: Dual wavelength colorimetry (420nm and 500 nm), Display: 20 digits x 2 lines LCD | Built-in thermal printer, Dimension (WDH): 330 x 515 x 485mm, ADAMS A1c Lite HA-8380V, Arkray, Arkray Co. Ltd., Inc., Japan
  • Compact and fast
  • Highly accurate measurement
  • HPLC technology
  • Easy to maintain
  • Cap-piercing method

 

1 item(s)
+

Table-top, Fully-automated, Principle: Reverse-Phase Cation Exchange Chromatography / High-Performance Liquid Chromatography (HPLC), Measured items: HbA1c, HbA2, HbF, HbS, HbC, HbE, HbD, Processing speed (Fast mode): 24 seconds per sample | (Variant mode): 58 seconds per sample, Measurement range: (HbA1c) 3 - 20%, 9 - 195 mmol/ mol; (HbF) 0-100% ; (HbA2) 2 - 20%, Sample consumption: Approx. 8 uL (Whole blood), Number of Samples: 50 samples (one-way transportation); 100 samples (loop transportation), Display: Color LCD with touch-screen, Sampling method: Cap piercing, Dimension (WDH): 530 x 530 x 530mm | Weight: 41kg, Adams A1c HA-8190V, Arkray, Arkray Co. Ltd., Inc., Japan

The ADAMS A1c, HA-8180 is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography).  HbA1c is a good parameter for long-term blood glucose monitoring in patients suffering from diabetes mellitus.

  • The fastest measurement of HbA2 in the world
  • Sample Stirring function
  • Highly accurate measurement
  • Easy-to-follow user interface
  • Easy-to-maintain
  • Cap-piercing method 
1 item(s)
+

Sample: Capillary whole blood, venous whole blood(Heparin), Sample Volume: 1.5 uL, Measurement range: HbA1c (IFCC): 20.2 - 151.4 mmol/ mol; HbA1c (NGSP): 4.0 - 16.0%, Processing speed: Approx. 90 seconds/ sample, Dimension (WxDxH)(mm): 220x326x298, The Lab 101, Arkray, Arkray Co. Ltd., Inc., Japan

The Lab 001 is an automatic HbA1c analyzer which uses capillary epectrophoresis methodology. Together with user-friendly basic functions and ergonomic design, The Lab 001 becomes the ideal choice for small/medium sized hospitals and clinics.

+

Horizontal type, Capacity: 74L/ 140L/ 198L/ 296L/ 383L, Temperatures: -40 to -60°C., Nature R refrigerant, Cyclopentane insulation, Vestfrost , VESTFROST SOLUTIONS, Denmark
Low Temperature Freezer -40 to -60°C

The VT low temperature freezers creates the possibility to maintain temperatures as low as -40 to -60°C. Supreme stability, reliability, user-friendliness and ease of cleaning make these freezers an ideal solution for laboratories and hospitals. Nature R refrigerant, cyclopentane insulation combined with recyclable materials make the freezers extremely eco-friendly.

  • Single compressor low-energy system
  • Plug & Play
  • User-friendly and maintenance-free
  • Low Operating Cost

1 item(s)
+

Vertical type, Data logging with USB extraction, Capacity: 256L, Temperature: -86°C, Dual Compressor System, Vestfrost , Vestfrost Solutions , Denmark
Premium Ultra Low Temperature -86°C Freezer

The VTS series offers a rare combination of streamlined and space-saving design with large capacity and advanced technology.

The ultra low temperature cabinet is designed as a personnal freezer for everyday use suitable for storage of sensitive articles such as research samples, chemicals, and viruses where contents must remain changeless.

  • Dual Compressor System
  • Temperature Graph in Controller
  • Data logging with USB extraction
  • Castors as standard

1 item(s)
+

Measurement wavelength: 5 wavelength LED (430, 500, 565, 635, and 760 nm), Test strips: Aution sticks series (10EA & 10PA), Aution screen MicroAlbumin/ Creatinine, Max sample load: 100 samples (circulation), Data memory: 2,700 tests (Including 200 control tests), Dimension (WxDxH)(mm): 530x530x530, AUTION MAX AX-4030, Arkray, Arkray Co. Ltd., Inc., Japan

 

AUTION MAX AX-4030 is the finest fully automated urine analyzer. Various measurements such as S.G., color-tone, turbidity and abnormal coloration are available, as well as ten qualitative analyses.

Parameters:

Glu, Pro, Bil, Uro, Ket, pH, Nit, Bld, Leu, Crea(Calculation items: Alb/ Crea ratio, Pro/ Crea ratio)

1 item(s)
+

Sample size: 80μ, Dimension: 270x238x146mm, Weight: 2.8kg, Application: Laboratory, ER, ICU, Clinics, GP office, Ambulance, etc., Standards: CE, NMPA, NGSP, IFCC, FIA METER , Wondfo, Wondfo Biotech Co., Ltd., China

Finecare™ FIA Meter Plus is a fluorescence immunochromatographic analysing system with internal temperature control, which helps diagnose conditions such as infection, diabetes, cardiovascular diseases, renal injury and cancers, etc.

  • Efficient Data Management: HIS/LIS connection;
  • Portable & Easy-to-use: Small in size, suitable for areas with limited spaces; Built-in temperature control
  • Cost-efficient: Broad test menu; Reagents can be stored at 2-30℃
  • Fast & Reliable: Results in 3-15 minutes, full traceability;
1 item(s)
+

Measurement wavelength: 4 wavelength LED (430, 565, 635, and 760 nm), Test strips: Aution sticks series (10EA & 10PA), Aution screen MicroAlbumin/ Creatinine, Processing speed: 514 samples per hour (Max processing mode: 7 seconds interval), Measurement method: Dual-wavelength reflection photometric method, Memory capacity: 530 measurement results, AUTION ELEVEN™ AE-4020, Arkray, Arkray Co. Ltd., Inc., Japan

Optimal device for urinalysis at small and medium-sized hospitals or clinics

Space-saving design: smaller than B4 paper size

High speed performance: 7 seconds per sample

 

1 item(s)
+

5.6-inch touch screen, Reagents: DS-I (NO.3) STD A & STD B (390/160 mL) 3-level QC (3*10 mL), Closed system with original reagents, Real-time display reagent volume, L-J graph for QC management, GE300, Genrui , Genrui Biotech Inc, China

GE300 is an easy-to-use, color touch screen electrolyte analyzer with throughput of 60 samples per hour based on ISE method. Auto calibration, sampling, cleaning to assure accurate results. Maintenance-free and long life electrode is another competitive feature to make it stand out and satisfy the customers.


1 item(s)
+

100 pcs, AUTION STICKS 10EA, Arkray, Arkray Co. Ltd., Inc., Japan

ARKRAY's AUTION Sticks(AUTION Sticks 10EA, 10PA, AUTION SCREEN) represent an enormous investment of company time and resources in producing the most advanced urine test strip for the medical profession. AUTION Sticks help ensure accurate measurements both visually and automatically.

Measurement items: Glu, Pro, Bil, Uro, Ket, pH, SG, Nit, Bld, Leu, Crea(Calculation items: Alb/ Crea ratio, Pro/ Crea ratio)

1 item(s)
 

P/342,160.00
Sample type: Whole blood, serum, plasma, urine, Measurement items: Na+, K+, Cl- (Easylyte Plus) | Na+, K+, Cl-, Ca++ or LI+, Analysis time: 55 seconds , Data Storage: Patient results — up to 128 samples; QC results — up to 20 each Normal, Low, and High, Calibration: Automatic or On-Demand, Easylyte Plus/ Expand, EasyLyte, Medica Corporation, USA

Medica Corporation’s EasyLyte® analyzer is a completely automated, microprocessor-controlled electrolyte system that uses ISE (Ion Selective Electrode) technology to make electrolyte measurements. The EasyLyte product line measures combinations of Na+, K+, Cl–, Li+, Ca++, and pH in whole blood, serum, plasma, or urine.

1 item(s)
+

Specificity: 98.39% (183/186), Panbio, Abbott Laboratories, USA

The Panbio® Dengue Early Rapid is a dengue NS1 antigen immunochromatographic assay. It is for the qualitative detection of NS1 antigen in serum, used as an aid in the clinical laboratory diagnosis of patients with clinical symptoms consistent with dengue fever. The Panbio® Dengue Early Rapid should be used in conjunction with other dengue serology tests.

  • NS1 antigen can be detected in serum from day 1 after onset of fever and up to day 9. This compares to IgM antibodies that are not detectable until days 3-54,5 .
1 item(s)
+