GLYCOHEMOGLOBIN (HbA1c) ANALYZER - AUTOMATED, LIFOTRONIC

H8, Lifotronic Technology Co. Ltd, China
Write a review
10 days
+

The Fully automated Lifotronic H8 Hemoglobin A1c Analyzer offers a fast throughput of HbA1c results in 13U seconds, with Hb variant detection, providing an outstanding solution for quick and reliable diabetic monitoring. No sample preparation and very little hands-on time by the operator are required for the H8 Analyzer

Advantages

  • HPLC Technology – Gold standard methodology of HbA1c detection
  • Multifunctional – HbA1c mode and Thalassaemia mode on the same platform
  • Fully Automated – One click to start analysis, no sample preparation and walk-away operation
  • Dual Wavelength Detection – Eliminate the background signal interference
  • Degasser – Remove air bubbles in lines and maintain stable system pressure  

Gold Standard of Diabetes Diagnose

Glycosylated hemoglobin (HbA1c) is widely recognized as a Gold Standard for monitoring diabetes, indicating the average plasma glucose concentration over 8~12 weeks.

HPLC Methodology

High-Performance Liquid Chromatography (HPLC), separates HbA1c directly with measuring the absorbance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbA1c testing result, excluding interference of variant and unstable hemoglobin like HbF. Standard Analysis Mode will report HbA1a、HbA1b、HbF、HbA1c、P3、HbA0 peak areas and ratio. And the result also includes IFCC, NGSP and ADAG value for diverse client needs.

Model Name:
H8
Manufacturer:
Lifotronic Technology Co. Ltd
Origin:
China

CHARACTERISTICS

Configuration:
Table-top
Operation:
Fully-automated

WARRANTY

Warranty Period:
One (1) year. Except for defects arising out of abuse and misuse of instrument

TECHNICAL DATA

Specification:
Methodology: Ion-Exchange HPLC | Gold standard methodology for HbA1C
Specification:
Sample Loader: 10
Specification:
Test range: 3-18% | High precision, CV ≤ 1.5 %
Specification:
Test Time: 130sec/Test for Variant mode | 6mins/Test for Thalassaemia mode
Specification:
Sample type: Venous Blood, Finger Peripheral, Lyophilized whole blood | Peripheral Blood: 500ul(150 Dilution Ratio
Specification:
Chromatography column: Available Tests ≥ 800tests
Specification:
Reagent kit: Eluent A, Eluent B, Eluent C, Hemolysin. Calibrator, QC Material (Weight sensor+1%)
Specification:
NGSP and IFCC certified
Specification:
Dimension: 580x500x520mm (HWD) | Weight: 50kg

Brochure (brochure_hba1c_lifotronic.pdf, 1,015 Kb) [Download]