HUMANOD, FULLY-AUTOMATED CHEMISTRY ANALYZER

Write a review
P/2,500,000.00 (and other offers)
(Including tax)
ACA-583

Throughput

  • Up to 266 tests / hour;

  • Up to 180 photometric tests / hour in Mono

    mode.

    Reagent System

  • Refrigerated reagent rotor controlled with Peltier elements;

  • Cooled to “cooled to 10°c/-2°c at normal laboratory conditions;

  • 32 reagent positions for 10 ml, 25 ml and 50 ml reagent bottles;

  • Reagent iD and automated programming of assays and calibrators via barcode;

  • Typical reagent consumption 250 ul per test;

  • All reagent positions can be assigned as r1, r2

    and r3;

  • Pre-heated needle with level detection, collision

    protection and integrated mixer.

    Sample System

• Sample rotor containing:

  • -  Outer segment with 50 barcode

  • -  Readable positions

  • -  Inner segment with 12 auxiliary positions

  • -  All positions fit 13x75 mm primary and

    secondary tubes and pediatric cups - all positions can be used for calibrators, controls, normal, pediatric and stat samples;

  • -  Sample probe with level detection, integrated mixer and collision protection;

  • -  Programmable dilution rations 1:5 up to 1:200 in one step increments with 3 possible diluents.

    Pipetting System

• 1000 μl reagent syringe:

Light Source

• Quartz-iodine lamp 12v-20W.

Wavelength Range

• 340 - 800 nm; • Optical unit with 8 position filter wheel; • Automatic wavelength selection • 340, 405, 505, 546, 578, 620, 660, 700 nm

standard installed; • Other wavelenghts available on request. Photometric Range • -0.1 to 3.0 absorbance; • Resolution 0.001 abs. Analytical Modes (Single, Dual and Triple Reagent System) • Kinetic measurement with linearity check; • Mono- and bichromatic end point measurement

with or without bichromatic reagent blank and/or

sample blank correction; • Two point measurement; with or without slope

blank; • Graphic plot of all measuring points; • Predilution and automatic reflex dilution as

needed; • Non-linear calibration curves; • Prozone check for immunology tests; • Cut-off declaration; • Calculated tests. Quality Control • Up to 15 different controls can be defined, 3 per

test; • Westgard rules; • Levey-Jennings plots; • Quality control statistics.

Water Consumption

• ~500 ml per hour max, continous operation.

Standards and Regulations

• CE-IVD; • CB. Dimensions (Benchtop, Self-Contained Unit) • 122x75x61cm(WxHxD);•Weight:95kg. Interface • Host: RS232 or Ethernet (TCP/IP) through

LIS-2A protocol.

Integrated PC

• Operating System: MS WindowsTM XP.

Bar Code Reader

• Hand held CCD bar code reader used for test requisition, reagent identification and automated programming of assays, controls and calibrators.

OPTIONS

Dry Electrode ISE Module

• Patented Solid State Electrode Technology; • Indirect Measurement • Dilution 1:14; • Measures Sodium, Potassium, Chloride and

CO2.

Positive Sample Identification

• Positive Sample Identification (PSID) via integrated barcode reader.

Printer

• Printer supported by MS WindowsTM.

ECO Kit

• Enables separate collection of concentrated measurement mixture and diluted wast

R1 volume 110 - 400 μl; R2 volume 0 - 180 μl; R3 volume 0 - 180 μl; Programmable in 1 μl steps;

μl sample syringe; sample volume 1-30 μl; Programmable in 0.1 μl steps.

Cuvette Rotor

  • Cost effective, semi-disposable cuvette rotor with 48 cuvettes, path length 7mm;

  • >10.000 tests per rotor;

  • Minimum measuring volume 220 μl;

  • Measuring temperature 37 ̊c, controlled by



Peltier elements. 