Throughput
-
Up to 266 tests / hour;
-
Up to 180 photometric tests / hour in Mono
mode.
Reagent System
-
Refrigerated reagent rotor controlled with Peltier elements;
-
Cooled to “cooled to 10°c/-2°c at normal laboratory conditions;
-
32 reagent positions for 10 ml, 25 ml and 50 ml reagent bottles;
-
Reagent iD and automated programming of assays and calibrators via barcode;
-
Typical reagent consumption 250 ul per test;
-
All reagent positions can be assigned as r1, r2
and r3;
-
Pre-heated needle with level detection, collision
protection and integrated mixer.
Sample System
• Sample rotor containing:
-
- Outer segment with 50 barcode
-
- Readable positions
-
- Inner segment with 12 auxiliary positions
-
- All positions fit 13x75 mm primary and
secondary tubes and pediatric cups - all positions can be used for calibrators, controls, normal, pediatric and stat samples;
-
- Sample probe with level detection, integrated mixer and collision protection;
-
- Programmable dilution rations 1:5 up to 1:200 in one step increments with 3 possible diluents.
Pipetting System
• 1000 μl reagent syringe:
Light Source
• Quartz-iodine lamp 12v-20W.
Wavelength Range
• 340 - 800 nm; • Optical unit with 8 position filter wheel; • Automatic wavelength selection • 340, 405, 505, 546, 578, 620, 660, 700 nm
standard installed; • Other wavelenghts available on request. Photometric Range • -0.1 to 3.0 absorbance; • Resolution 0.001 abs. Analytical Modes (Single, Dual and Triple Reagent System) • Kinetic measurement with linearity check; • Mono- and bichromatic end point measurement
with or without bichromatic reagent blank and/or
sample blank correction; • Two point measurement; with or without slope
blank; • Graphic plot of all measuring points; • Predilution and automatic reflex dilution as
needed; • Non-linear calibration curves; • Prozone check for immunology tests; • Cut-off declaration; • Calculated tests. Quality Control • Up to 15 different controls can be defined, 3 per
test; • Westgard rules; • Levey-Jennings plots; • Quality control statistics.
Water Consumption
• ~500 ml per hour max, continous operation.
Standards and Regulations
• CE-IVD; • CB. Dimensions (Benchtop, Self-Contained Unit) • 122x75x61cm(WxHxD);•Weight:95kg. Interface • Host: RS232 or Ethernet (TCP/IP) through
LIS-2A protocol.
Integrated PC
• Operating System: MS WindowsTM XP.
Bar Code Reader
• Hand held CCD bar code reader used for test requisition, reagent identification and automated programming of assays, controls and calibrators.
OPTIONS
Dry Electrode ISE Module
• Patented Solid State Electrode Technology; • Indirect Measurement • Dilution 1:14; • Measures Sodium, Potassium, Chloride and
CO2.
Positive Sample Identification
• Positive Sample Identification (PSID) via integrated barcode reader.
Printer
• Printer supported by MS WindowsTM.
ECO Kit
• Enables separate collection of concentrated measurement mixture and diluted wast
R1 volume 110 - 400 μl; R2 volume 0 - 180 μl; R3 volume 0 - 180 μl; Programmable in 1 μl steps;
μl sample syringe; sample volume 1-30 μl; Programmable in 0.1 μl steps.
Cuvette Rotor
-
Cost effective, semi-disposable cuvette rotor with 48 cuvettes, path length 7mm;
-
>10.000 tests per rotor;
-
Minimum measuring volume 220 μl;
-
Measuring temperature 37 ̊c, controlled by
Peltier elements.