Mathew Kieran Trading
MATHEW KIERAN TRADING

Distributor of Laboratory and Medical Supply
Address: 20 Efficience Street, Novaliches, Quezon City

Vendor filters

Origin
Packaging
Price
Vendor
Brand
Variation: Feature

Vendor productsProducts found: 44

Ask a question
P/10,920.00
Secondary Sensitivity: 98.8%, Specificity: 91.6%., Panbio, Abbott Laboratories, USA

CONVENIENT. In the Panbio® Dengue Duo Cassette, IgM and elevated IgG are determined simultaneously using a single addition of serum, plasma or whole blood, enabling differentiation between primary and secondary infection through a single application of specimen. In primary infections, serum IgM antibodies can be detected from dengue patients as early as 3 to 5 days after the onset of fever.

QUICK. In primary infections, serum IgM antibodies can be detected from dengue patients as early as 3 to 5 days after the onset of fever.

RELIABLE. Dengue Duo Cassette can detect the high levels of IgG characteristic of secondary infections and IgM levels associated with primary dengue with high sensitivity and specificity.

1 item(s)
+

P/100,650.00 (Including tax)
Display Type: LCD, 2 × 16 Characters, Instrument Box: 200 mm x 170 mm x 70 mm, Reader Pen: (L) 144 mm; (D) 29.5 mm, Batteries: Rechargeable NiMH Batteries Only, Size AA 1.2 V, Recharge 8–18 hours, Battery Charger: Mascot Type 9725 or Equivalent, NYCOCARD READER II, Abbott, Abbott Laboratories, Norway
The NycoCard™ READER II leverages robust technology with proven quality. The instrument is factory calibrated to ensure accurate results. It is a portable, point-of-care instrument designed for rapid and reliable measurements of the NycoCard test. Lot-specific calibration by the operator is not necessary. Only a simple black/white calibration at startup and instrument is ready for use.
1 item(s)
+

P/8,555.00 (Including tax)
3 minutes test time, 5 µL sample volume, Measuring range: (Whole blood) 8-200 mg/L;Serum or plasma samples: 5-120 mg/L , NYCOCARD CRP, Abbott, Abbott Laboratories, USA

The measurement of CRP provides information for the detection and evaluation of infection, tissue injury, inflammatory disorders and associated diseases.

1 item(s)
+

Sample: Whole blood, plasma, serum, diluted urine, Calibration: automatic or on-demand, Measuring range: K (0.50-15.0 mmol/L); Na/ Cl (30.0-200.0 mmol/L); Ca (0.10-5.00 mmol/L); pH (7.00-9.00 unit); Li (0.30-3.00 mmol/ L), Data storage: up to 500 patient results, Dimension: 440 x 380 x 350mm (HxWxD), 10kg, STATLYTE-C, KGI, Kapitol Group International, Ltd., Taiwan
  • No handling of waste
  • Economic reagent cost per test
  • Simple and easy operation
  • Stable and accurate testing result
  • Auto sampler support
  • Long shelf-life of ISE and reagent
1 item(s)
+

Touch screen: Yes, colored, Sample memory: 50,000, QC software: Yes, Number of Reagents: 2, Time to result: <50 seconds, SWELAB ALFA PLUS STANDARD, Boule, Boule Medical AB, Sweden
Swelab Alfa Plus hematology analyzers combine unmatched reliability with maximum ease of operation. Fast and user-friendly, highly accurate results are backed up by built-in quality monitoring and low instrument maintenance. In addition, a complete system solution comprising instruments, reagents and QC materials ensures outstanding performance time after time
1 item(s)
+

STAT prioritization with priority processing for every sample, Real time test results, Intuitive user interface, Bi-directional interface to LIS, Broadest test menu for patient and donor testing, NEO IRIS, Immucor, Immucor, USA

Capture solid-phase technology for antibody screening and identification—the most sensitive test method for detecting clinically significant antibodies

NEO Iris™ is Immucor’s 6th generation analyzer and offers maximum productivity with the highest type and screen throughput on the market while providing your laboratory remarkable flexibility.

1 item(s)
+

Sample and reagent loading bay: Accommodates 20 samples and 16 liquid reagents. Single probe pipettor; steel, teflon- coated probe, Micro-strip loading bay: Accommodates 32 strips. All strips feature 2D bar codes for traceable resource management, Automated processing: Forced-air incubator reduces TAT, Continuous flow washer. Self-balancing centrifuge. Image analysis reader provides real time test results, Intuitive user interface: Windows XP operating system. Color, touchscreen monitor, GALILEO ECHO LUMENA , Immucor, Immucor, USA
Capture solid-phase technology for antibody screening and identification—the most sensitive test method for detecting clinically significant antibodies...
1 item(s)
+

Normal Control, 10 x 5 ml, ELITROL, Elitech, Elitech Group Clinical Systems, France
ELITechGroup Clinical Systems features a comprehensive menu of ready-to-use, liquid-stable reagents. Over 100 available assays with flexible reagent packaging and methods referenced to industry standards. ELITech is committed to ongoing development of new methods to provide a growing line of superior chemistry test menus.
1 item(s)
 

Table-top, Fully-automated, One (1) year. Except for defects arising out of abuse and misuse of instrument, 32 Reagent position, and 50 barcode readable sample positions, Patented Solid State Electrode Technology, Cost effective, semi-disposable cuvette rotor with 48 cuvettes, Automatic wavelength selection: 340, 405, 505, 546, 578, 620, 660, 700 nm, Dimensions: 122x75x61cm(WxHxD);•Weight:95kg., SELECTRA PRO M, Elitech, Elitech Group Clinical Systems, France

Selectra Pro M

Setting the new standard in BenchTop chemistry. Throughput is up to 180 photometric tests/hour, plus optional dry ISE

1 item(s)
+

Test time: 6 seconds (Glucose); 150 seconds (Cholesterol); 20 seconds (Uric acid), Technology: Electrode-based sensor, Sample volume: 0.8 uL (Glucose); < 15 uL (Cholesterol & Uric Acid), Power supply: 15v (AAA) x 2pcs, Life of battery: Apprx 1000 tests, BEST CHECK 3 IN 1 , KGI, Kapitol Group International, Ltd., Taiwan
  • For Glucose, Cholesterol and uric acid testing
  • One-step operation
  • Large LCD design
  • Less blood sample
  • Rapid test result
  • No interference with Maltose, Lactose, Galactose, or Xylose
1 item(s)
+

WAVELENGTH RANGE • Automatic by 12 positions filterwheel; 340, 405, 505, 546, 578 and 620 nm; 6 positions for optional filters., FLOWCELL: Metal, with quartz windows, measuring volume 30 μl., MULTIPLE TESTING: Up to nine replicates; Means, SD and CV., CALIBRATION: Factor, one-point, two-point and multi-point; Automatic on 1 standard (linear mode); Automatic on up to 10 standards (non linear mode), QUALITY CONTROL:Two controls per test; • QC survey of last 30 control measurement ; • Levey Jenning plot; • High/low flags., MICROLAB 300, Elitech, Elitech Group Clinical Systems, France

The Microlab 300 is a true semi-automated clinical chemistry analyzer in all its glory. A system that is designed as a clinical chemistry analyzer and not as a standard photometer. Thousands of users have experienced the proven reliability and high performance of the Microlab all over the world. Robust, compact, and easy-to-use, it is ideal for smaller or satellite laboratory locations. Together with a superior menu of ready-to-use, liquid-stable reagents, the Microlab 300 covers primary, STAT, or backup testing needs. This system offers minimal maintenance and effective use of consumables to provide a truly cost-effective operation.

1 item(s)
+

Aspiration volume: CBC - 20 uL; CBC + Diff - 25 uL, Sampling System: Open tube aspiration, Data storage capacity: 50,000, 60 samples/hour in cbc mode; 45 samples/hour in differential mode, Printout: External laser printer or inkjet printer, SWELAB LUMI, Boule, Boule Medical AB, Sweden
Swelab Lumi is an entry-level 5-part hematology analyzer intended for the cost-minded clinical laboratory. The user-friendly design makes system operations easy. Robust software and hardware components ensure a reliable instrument performance.
1 item(s)
+