Table-top, Fully-automated, Up to 200 tests/hour, up to 400 tests/hour with ISE , 80 positions for reagents and 40 positions for samples in 24-hour refrigerated compartment (2~12°C), Reagent volume: 10~250μl, step by 0.5μl | Sample volume: 2~45μl, step by 0.1μl, Reagent/Sample probe: Liquid level detection, vertical collision protection and inventory checking, reagent pre-warming , Probe cleaning: Automatic washing for interior and exterior Carry over < 0.05%, Cuvette: 40 cuvettes | Reaction volume: 100~360μl | Operating temperature: 37°C±0.1°C, ISE Module (optional): Measuring K+, Na+, Cl-, Light Source: Wavelength: Halogen-tungsten lamp | 8 wavelengths, 340nm、405nm、450nm、 510nm、546nm、578nm、630nm、670nm, Water Consumption: ≤ 2 L/H | Dimension: 690 mm (length) ×580 mm (depth) ×595 mm (height) | , BS-240, Mindray, Mindray Bio-Medical Electronic Co. Ltd, China
BS-240 is a “CUTE”, multi-functional benchtop clinical chemistry analyzer with a throughput at 200 T/H. Though with a compact size, it has achieved a host of advanced functions never before found on a like product in the market, making it an optimal chemistry solution for small laboratories and a back-up tool for mid-to-high end laboratories.
1 item(s)
+

Table-top, Fully-automated, 35 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC, LIC%, LIC#, ALY%, ALY#, PLT Clumps#, PLT Clumps%, Lip#, Lip%, NRBC#, NRBC%., 3 histograms: WBC, RBC or PLT | 3 Scatter grams: WBC, Sample volume: Predilute - 20µL | Whole blood - 15 µL | Capillary Whole blood mode: 15 μL, Troughput: Up to 60 samples per hour, Display: 10.4 inch large TFT touch screen , Reagent: Diluent, DIFF lyse, LH lyse, probe cleanser, Data Storage Capacity: Up to 40,000 results including numeric and graphical information, Communication: LAN Port supports HL7 protocol | Interface: USB, LAN Support Uni- or bi-directional LIS, Dimensions: (DxWxH) 400mm*320mm*410mm | Weight: 24Kg, BC-5120, Mindray, Mindray Bio-Medical Electronic Co. Ltd., China

Impedance method for RBC and PLT counting Cyanide free reagent for hemoglobin test Flow Cytometry (FCM) + Laser scatter + Chemical dye method for WBC 5-part differential analysis and WBC counting

Parameters:

  • 35 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC, LIC%, LIC#, ALY%, ALY#, PLT Clumps#, PLT Clumps%, Lip#, Lip%, NRBC#, NRBC%.
  • 3 histograms: WBC, RBC ir PLT
  • 3 Scatter grams: WBC

Sample volume:

  • Predilute:      20µL
  • Whole blood: 15 µL

Throughput:

  • Up to 60 samples per hour

 

1 item(s)
+

Table-top, Fully-automated, Principles: SF Cube ^ Cell Analysis Technology ^S: Scatter; F: Fluorescence; Cube: 3D analysis; Colorimetric method; Photometric method, Number of reportable parameters: 41 (WBC Bas# Bas% Neu# Neu% Eos# Eos% Lym# Lym% Mon# Mon% IMG# IMG% RET%* RET#* RHE* IRF* LFR* MFR* HFR* RBC HGB MCV MCH MCHC RDW-CV RDW-SD HCT NRBC# NRBC% PLT PLT-I PLT-H PLT-O* MPV PDW PCT P-LCR P-LCC IPF ESR), Sample volume CD (whole blood): 25ul | CD+ESR (whole blood): 160ul | Predilute: 20ul, Throughput: CD 80tests/hour | CDR 45tests/hour | CD+ESR 40tests/hour, Data storage capacity: Up to 150,000 results including numeric and graphical information *, Voltage: 100V-240V~ (±10%) | Frequency: 50Hz/60Hz (±1Hz) | Power input: 600VA, External output: LANx1 , USB x 4 (Specifications: DC 5V; 500mA; USB2.0 x 3; USB3.0 x 1 ), Ambient temperature: 10°C ~ 35°C | Relative humidity: 30% ~ 85%, Dimensions: 840 x 655 x 600mm (DWH) | Weight ≤70.6Kg, BC-760/ 780, Mindray, Mindray Bio-Medical Electronic Co. Ltd., China
MINDRAY BC 760 & 780 
 
CBC + DIFF + ESR in one test provides reliable ESR results with greater ease
The BC-700 series integrates an automatic ESR module in a hematology analyzer. It can also generate both CBC & ESR results in one test within 1.5 min. In addition, it saves the costs that would otherwise be incurred for the purchase, maintenance, consumables, and storage space of a separate ESR analyzer. Compared with the traditional Westergren method, this method performs better in quality traceability, repeatability, speed, safety, and level of automation.
 
1 item(s)
+

Table-top, Fully-automated, Impedance method for WBC, RBC, PLT counting. Cyanide-free reagent for hemoglobin test, 21 parameters. WBC, Lym%, Mid%, Gran%, Lym#, Mid#, Gran#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC, Sample volume: Predilute - 20µL | Whole blood - 9 µL, Troughput: Up to 70 samples per hour, Display: 10.4 inch large TFT touch screen , Reagent: M-30D Diluent, M-30CFL lyse, probe cleanser, Data Storage Capacity: Up to 500,000 results including numeric and graphical information, Communication: LAN Port supports HL7 protocol | Interface: USB, LAN Support Uni- or bi-directional LIS, Dimensions: (DxWxH) 410mm*300mm*400mm | Weight: 20Kg, BC-5120, Mindray, Mindray Bio-Medical Electronic Co. Ltd., China
  • CBC+3-DIFF, 21 parameters+3 Histograms
  • Throughput: up to 60 samples per hour
  • 10.4 inch TFT touch screen
  • Only three reagents needed
  • Open vial sampling
  • Large storage capacity: up to 400,000 samples 
  • Original QC, calibrators and reagents
1 item(s)
+